{"title":"Catalogue \u003e First Aid Kit \u003e Urine \u003e Probes","description":"","products":[{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch16","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch16","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eThe Fortune 2-way Foley catheter with 5 ml balloon is a disposable medical device made of high quality transparent silicone. The product is designed to help drain the patient's urine. It consists of a straight cylindrical tip and two holes at the distal end. One way is intended to drain the urine and the other way inflates and deflates the catheter balloon. It has a valve for syringe fittings as well as a contrast strip along the length of the catheter. It can be attached to the user's bladder, preventing accidental leakage. It is suitable for long-term urethral catheterisation and is suitable for all patients. Suitable after surgical procedures.\u003c\/p\u003e\n\u003cp\u003eIts use for therapeutic purposes is appropriate, as it improves the quality of life of the patient with a condition that prevents him\/her from controlling diuresis. It enables the physician to collect accurate, real-time information on the amount of urine of his patient. It can be used in operating theatres, intensive care areas or general care floors, among others. The catheter is painless to insert and remove, especially relevant in chronic treatments where urination difficulties arise. It is excellent for carrying out procedures effectively and safely.\u003c\/p\u003e\n\u003ch2\u003eWho is it suitable for?\u003c\/h2\u003e\n\u003cp\u003eThe Fortune 2-Way Balloon Catheter 5 ml size ch16 is especially recommended for patients with urinary incontinence, for diuresis control procedures and in post-operative situations.\u003c\/p\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003eIn the case of men, the foreskin should be removed with the help of sterile gauze and the penis should be placed in a vertical position until 7-8 cm of the catheter is inserted. With the penis in a horizontal position, continue inserting the catheter until urine emanates. A further 5 cm should be advanced to ensure correct insertion of the catheter into the bladder.\u003c\/p\u003e\n\u003cp\u003eIn women, it is sufficient to hold the catheter with the dominant hand and gently insert it through the meatus until urine refluxes. Insert a further 5 cm to ensure correct placement.\u003c\/p\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eDo not use the Fortune 2-way Foley catheter and balloon if there are injuries to the urethra related to pelvic trauma. Also not if there is suspicion of urethral rupture.\u003c\/p\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eTransparent silicone.\u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43626821157041,"sku":"460873","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch16ch_e8b995a6-d97a-42bc-9438-29eb62c04d41.webp?v=1784338859"},{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch18","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch18","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eThe Fortune 2-way Foley catheter with built-in balloon is a urinary catheter made of medical grade silicone. Its tubing is transparent to allow visual inspection and observation of fluids. The soft balloon that has been evenly inflated makes it easy for the tube to adhere to the bladder. This creates a completely smooth surface that reduces friction within the urethra, and therefore patient discomfort.\u003c\/p\u003e\n\u003cp\u003eIt incorporates a curved, cylindrical and delicate tip in order to reduce possible trauma when inserting and removing the catheter. It has two holes that support the catheterisation of the urethra permanently and durably.\u003c\/p\u003e\n\u003cp\u003eThe Foley catheter has two arms: one to facilitate the drainage of the patient's urine and the other where the balloon is inflated with sterile water. The catheter is made of natural latex which is coated with medical grade silicone. It incorporates a lateral eye to minimise the possibility of trauma to the urethral mucosa.\u003c\/p\u003e\n\u003cp\u003eIt is hypoallergenic, non-toxic and free of fever-causing agents (pyrogens). This catheter has been sterilised with ethylene oxide and is presented in individual double sterilised packaging. Another important feature of the Fortune 2-way catheter is that it helps to reduce the accumulation of urinary sediment. The catheter should be used immediately after removal from its original packaging to avoid contamination.\u003c\/p\u003e\n\u003ch2\u003eWho is it suitable for?\u003c\/h2\u003e\n\u003cp\u003eThe Fortune 2-Way Foley catheter is suitable for people with incontinence and urinary retention, who must use a urinary catheter to allow fluids to pass to and from the bladder. It is also recommended for people who are undergoing post-operative prostate or genital surgery and for those with chronic conditions where urination is difficult.\u003c\/p\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003eAsepsis must be ensured by following established protocols, using a sterile glove. The balloon is used only with distilled or sterile water. The Foley catheter must be lubricated before insertion. Apply gentle pressure on the valve in order to evacuate and fill the balloon.\u003c\/p\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eNot to be used in patients with hypersensitivity to latex, or in those with organic rejection of the catheter, in which case it should be discontinued immediately.\u003c\/p\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eLatex, Acryl Butyl Styrene (ABS), steel spring, silicone coated catheter.\u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43626821091505,"sku":"460881","price":7.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch18ch_04b4b57e-dbd6-4b1a-8296-e1a7d7d6029a.webp?v=1784338861"},{"product_id":"fortune-foley-probe-2-way-5-ml-balloon-size-ch14","title":"FORTUNE Foley probe 2 way 5 ml balloon size ch14","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eFORTUNE Foley catheter 2 way balloon 5 ml is a medical device for regular use by people who have problems urinating normally, mainly due to bladder or urethral problems or other conditions. It is made of silicone and medical grade plastic, which guarantees excellent tolerability when in contact with the skin.\u003c\/p\u003e\n\u003cp\u003eIts balloon has a capacity of between 5 to 10 ml or cc, while the tube has a length of 420 mm. It also has a built-in radiopaque line that will facilitate the location of the intubated tube.\u003c\/p\u003e\n\u003cp\u003eThe balloon is soft and inflates evenly, helping to secure the tube against the bladder. The tube is transparent, allowing for quick visual inspection and observation of the fluid. This feature is ideal for easily checking the status of the urinary system.\u003c\/p\u003e\n\u003cp\u003eThe tip of the catheter has a rounded design and is soft to the touch to help reduce the trauma and discomfort caused by insertion or removal of the catheter.\u003c\/p\u003e\n\u003cp\u003eThe probe cap is individually packaged and sterilised to ensure maximum protection and to avoid any possible contamination and infection. In addition, the rest of the product is also sterilised and therefore uses double sterile packaging.\u003c\/p\u003e\n\u003cp\u003eIt has been developed and manufactured under the high quality standards of the PRIM brand, a leading Spanish company in the health and medical sector. It is part of a range of urology catheters called FORTUNE and is the most standard.\u003c\/p\u003e\n\u003ch2\u003eWho is it suitable for?\u003c\/h2\u003e\n\u003cp\u003eIt is indicated for men who need extra help to facilitate the expulsion of urine. As well as for permanent or long-term urethral catheterisation.\u003c\/p\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003eIt should preferably be inserted by a professional urologist to ensure correct insertion.\u003c\/p\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eKeep away from any source of heat or ignition strong enough to melt the silicone or plastic of the tube. Remove from its packaging only when the catheter is to be inserted to avoid contamination. Do not use if you are allergic or hypersensitive to silicone or any of its other components. Keep out of reach of small children.\u003c\/p\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eMedical grade silicone, clear medical grade tubing, radiopaque line and probe cap.\u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43505370398897,"sku":"460865","price":7.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch14ch_637d122e-9721-4be6-b078-5989da92cbec.webp?v=1784344039"},{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch20","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch20","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eFortune Foley Catheter 2-Way Balloon 5 ml Size Ch20 is a medical device used to drain the urinary bladder. It is designed to remain in the bladder for an extended period of time. The catheter consists of a flexible silicone tube with a balloon at one end and an outlet at the other end for connection to a urine drainage system. The balloon is inflated with water or air after the catheter is inserted into the bladder, which prevents the catheter from slipping out of the bladder.\u003c\/p\u003e\n\u003ch2\u003eWho is it indicated for?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSpinal cord or peripheral nervous system injuries that affect bladder function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbdominal or pelvic surgeries that may affect bladder function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcute or chronic prostatitis, which may cause urinary retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ebenign prostatic hypertrophy, which may cause obstruction of urine flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eprostate cancer, which can cause obstruction of the urethra and urinary retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStress urinary incontinence in patients with overactive bladder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospitalised patients who are unable to urinate voluntarily due to their clinical condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003ePlease note that the two-way silicone Foley catheter with balloon is a medical device and must be inserted by a trained professional.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eWash your hands and put on sterile gloves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect the appropriate size of the two-way balloon silicone Foley catheter based on the patient's needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLubricate the catheter with a water-soluble lubricant to facilitate insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean the patient's genital area with an antiseptic solution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the two-way silicone Foley balloon catheter into the patient's urethra slowly until it reaches the bladder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInflate the balloon at the end of the catheter with water or air, according to the manufacturer's instructions, to secure the catheter in the bladder and prevent displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the other end of the catheter to a urine collection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegulate the flow of urine through the valve on the catheter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeriodically check the condition of the catheter, the patient's urinary function and the urine collection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen catheter removal is necessary, inflate the balloon to detach the catheter from the bladder wall and remove the catheter slowly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eActive urinary tract infection or suspected urinary tract infection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive urethral haemorrhage or suspected urethral haemorrhage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKnown hypersensitivity to the catheter material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eLatex, silicone, polyurethane.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43626977919153,"sku":"460899","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch20ch_3197ae44-cd2b-4aec-95ea-41d309449218.webp?v=1784344040"},{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch22","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch22","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eFortune Foley Catheter 2-Way Balloon 5 ml Size Ch22 is a medical device used to drain the urinary bladder. It is designed to remain in the bladder for an extended period of time. The catheter consists of a flexible silicone tube with a balloon at one end and an outlet at the other end for connection to a urine drainage system. The balloon is inflated with water or air after the catheter is inserted into the bladder and this prevents the catheter from slipping out of the bladder.\u003c\/p\u003e\n\u003ch2\u003eWho is it indicated for?\u003c\/h2\u003e\n\u003cp\u003eFor the following profiles:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinal cord or peripheral nervous system injuries affecting bladder function.\u003c\/li\u003e\n\u003cli\u003eAbdominal or pelvic surgeries that may affect bladder function.\u003c\/li\u003e\n\u003cli\u003eAcute or chronic prostatitis, which may cause urinary retention.\u003c\/li\u003e\n\u003cli\u003ebenign prostatic hypertrophy, which may cause obstruction of urine flow.\u003c\/li\u003e\n\u003cli\u003eprostate cancer, which can cause obstruction of the urethra and urinary retention.\u003c\/li\u003e\n\u003cli\u003eStress urinary incontinence in patients with overactive bladder.\u003c\/li\u003e\n\u003cli\u003eHospitalised patients who are unable to urinate voluntarily, due to their clinical condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003ePlease note that the two-way silicone Foley catheter with balloon is a medical device that must be inserted by a trained professional.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eWash your hands and put on sterile gloves.\u003c\/li\u003e\n\u003cli\u003eSelect the appropriate size of the two-way silicone Foley balloon catheter based on the patient's needs.\u003c\/li\u003e\n\u003cli\u003eLubricate the catheter with a water-soluble lubricant to facilitate insertion.\u003c\/li\u003e\n\u003cli\u003eClean the patient's genital area with an antiseptic solution.\u003c\/li\u003e\n\u003cli\u003eInsert the two-way silicone Foley balloon catheter into the patient's urethra slowly until it reaches the bladder.\u003c\/li\u003e\n\u003cli\u003eInflate the balloon at the end of the catheter with water or air, according to the manufacturer's instructions, to secure the catheter in the bladder and prevent displacement.\u003c\/li\u003e\n\u003cli\u003eConnect the other end of the catheter to a urine collection system.\u003c\/li\u003e\n\u003cli\u003eRegulate the flow of urine through the valve on the catheter.\u003c\/li\u003e\n\u003cli\u003ePeriodically check the condition of the catheter, the patient's urinary function and the urine collection system.\u003c\/li\u003e\n\u003cli\u003eWhen catheter removal is necessary, inflate the balloon to detach the catheter from the bladder wall and remove the catheter slowly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eNote:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eActive urinary tract infection or suspected urinary tract infection.\u003c\/li\u003e\n\u003cli\u003eActive urethral bleeding or suspected urethral bleeding.\u003c\/li\u003e\n\u003cli\u003eKnown hypersensitivity to catheter material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eLatex, silicone and polyurethane.\u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43505370562737,"sku":"460907","price":9.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch22ch_4d1f561c-830b-464b-a5ee-90ed94ddcaf5.webp?v=1784344040"},{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch12","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch12","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eFortune Foley Catheter 2-Way Balloon 5 ml PRIM Size Ch12 is a medical device used to drain the urinary bladder. It is designed to remain in the bladder for an extended period of time. The catheter consists of a flexible silicone tube with a balloon at one end and an outlet at the other end for connection to a urine drainage system. The balloon is inflated with water or air after the catheter is inserted into the bladder and this prevents the catheter from slipping out of the bladder.\u003c\/p\u003e\n\u003ch2\u003eWho is it indicated for?\u003c\/h2\u003e\n\u003cp\u003eFor these profiles:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSpinal cord or peripheral nervous system injuries that affect bladder function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbdominal or pelvic surgeries that may affect bladder function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcute or chronic prostatitis, which may cause urinary retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ebenign prostatic hypertrophy, which may cause obstruction of urine flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eprostate cancer, which can cause obstruction of the urethra and urinary retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStress urinary incontinence in patients with overactive bladder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospitalised patients who are unable to urinate voluntarily, due to their clinical condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003ePlease note that the two-way silicone Foley catheter with balloon is a medical device that must be inserted by a trained professional.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eWash your hands and put on sterile gloves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect the appropriate size of the two-way silicone Foley balloon catheter based on the patient's needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLubricate the catheter with a water-soluble lubricant to facilitate insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean the patient's genital area with an antiseptic solution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the two-way silicone Foley balloon catheter into the patient's urethra slowly until it reaches the bladder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInflate the balloon at the end of the catheter with water or air, according to the manufacturer's instructions, to secure the catheter in the bladder and prevent displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the other end of the catheter to a urine collection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegulate the flow of urine through the valve on the catheter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeriodically check the condition of the catheter, the patient's urinary function and the urine collection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen catheter removal is necessary, inflate the balloon to detach the catheter from the bladder wall and remove the catheter slowly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eNote:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eActive urinary tract infection or suspected urinary tract infection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive urethral bleeding or suspected urethral bleeding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKnown hypersensitivity to the catheter material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eLatex, silicone, polyurethane.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43505379508401,"sku":"460857","price":8.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch12ch_9c3f8a2e-49af-45d4-ae10-84ab7f235023.webp?v=1784344592"},{"product_id":"fortune-foley-probe-2-way-balloon-5-ml-size-ch24","title":"Fortune Foley Probe 2-Way Balloon 5 ml Size Ch24","description":"\u003ch2\u003eWhat is it and what is it for?\u003c\/h2\u003e\n\u003cp\u003eThe Fortune 2-way Foley catheter with balloon manufactured by PRIM is a medical device designed for the elderly or adults who have difficulty urinating normally. Its use is based on the fact that one end of the catheter must pierce the bladder, allowing the accumulated urine to pass to the outside. The other end of the catheter is attached to a disposable medical bag which, when filled to a reasonable capacity, must be discarded and replaced with a new one.\u003c\/p\u003e\n\u003cp\u003eThis probe has the specific features of a 24 FR size with a 5 to 10 ml \/ cc balloon and a 420 mm long tube. Radiopaque line and probe cap are included.\u003c\/p\u003e\n\u003cp\u003eThe material of which the probe is made is medical silicone, this will help the product not to be rejected by the body and to have a high biocompatibility. The tube is transparent to allow observation of the fluid withdrawn from the bladder to see if it is working properly.\u003c\/p\u003e\n\u003cp\u003eThe balloon is soft and is placed in the portion of the tube that is attached to the bladder. Its function is to help fix the catheter in place. The very end has a rounded and very soft tip so that, at the time of insertion and removal, it does not cause any trauma or mild pain.\u003c\/p\u003e\n\u003ch2\u003eWho is it suitable for?\u003c\/h2\u003e\n\u003cp\u003eIt is mainly indicated for men who need a catheter for any justifiable medical reason. Its specific use is to help drain urine that accumulates in the bladder and transfer it to a disposable medical bag.\u003c\/p\u003e\n\u003ch2\u003eInstructions for use\u003c\/h2\u003e\n\u003cp\u003eIt is advisable to allow a healthcare professional to place the catheter properly and optimally to prevent complications. It is also advisable to take antibiotics when changing the catheter to reduce the likelihood of infection.\u003c\/p\u003e\n\u003ch2\u003eContraindications\u003c\/h2\u003e\n\u003cp\u003eNever bring the catheter close to sources of heat and ignition so that the silicone does not deform. Avoid removing it from its sterile case if it is not going to be used, once it is contaminated it cannot be used. Keep out of reach of children. Do not attempt to insert if you do not have the necessary knowledge or tools to do so. Avoid use in individuals with hypersensitivity to silicone.\u003c\/p\u003e\n\u003ch2\u003eComposition\u003c\/h2\u003e\n\u003cp\u003eMedical grade silicone.\u003c\/p\u003e","brand":"PRIM","offers":[{"title":"Default title","offer_id":43502727069873,"sku":"460915","price":8.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/fortune-sonda-foley-2-vias-balon-5-ml-tamano-ch24ch_cba88e22-e2c2-4943-9718-dc6d75f56bcc.webp?v=1784346033"},{"product_id":"rusch-brillant-silicone-probe-ch-12","title":"Rüsch Brillant Silicone Probe Ch-12","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463110881457,"sku":"RU8470004564594","price":10.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-slicona-12-ch_a3b07ff4-496c-4489-8c41-3132cdd7f22d.webp?v=1784336124"},{"product_id":"rusch-brillant-silicone-probe-ch-14","title":"Rüsch Brillant Silicone Probe Ch-14","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463110979761,"sku":"RU8470004564679","price":11.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-14ch_d6132942-b6a1-481f-b327-942820a9576b.webp?v=1784336125"},{"product_id":"rusch-brillant-silicone-probe-ch-16","title":"Rüsch Brillant Silicone Probe Ch-16","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463111078065,"sku":"RU8470004564754","price":9.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-16ch_7eafdb09-f30c-47cd-933e-6eeaf0de256e.webp?v=1784336125"},{"product_id":"rusch-brillant-silicone-probe-ch-22","title":"Rüsch Brillant Silicone Probe Ch-22","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463111143601,"sku":"RU8470004565096","price":10.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-22ch_3bfb4134-7c7b-40d7-a2a1-49eb8d6b490b.webp?v=1784336127"},{"product_id":"rusch-brillant-silicone-probe-ch-20","title":"Rüsch Brillant Silicone Probe Ch-20","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463111209137,"sku":"RU8470004564914","price":9.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-20ch_95a4346e-3a13-4658-a110-d20132e8e1ae.webp?v=1784336127"},{"product_id":"rusch-brillant-silicone-probe-ch-18","title":"Rüsch Brillant Silicone Probe Ch-18","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463111274673,"sku":"RU8470004564839","price":9.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-18ch_ca7bbc90-4e3e-43dd-902c-c4a2509f0af9.webp?v=1784336126"},{"product_id":"rusch-brillant-silicone-probe-ch-24","title":"Rüsch Brillant Silicone Probe Ch-24","description":"\u003cp\u003eThe RÜSCH silicone bladder catheter has two channels and a balloon with a capacity of approx. 10ml.\u003cbr\u003eThe silicone is biocompatible, biostable and non-alienic. Its surface prevents the formation of incrustations.\u003cbr\u003eHigh drainage capacity, suitable for long-term use.\u003cbr\u003eHigh level of patient comfort.\u003cbr\u003eApproximate length of 41cm.\u003cbr\u003eThe catheter is flexible, has optimal tissue compatibility and does not cause irritation to mucous membranes.\u003cbr\u003eFull tip according to Tiemann.\u003cbr\u003eValve for Luer and Luer-lock syringe fittings.\u003cbr\u003eFor single use only.\u003cbr\u003eSterile.\u003c\/p\u003e\n\u003ch2\u003ePRECAUTIONS\u003c\/h2\u003e\n\u003cp\u003eAfter several weeks, the balloon catheter usually shows no symptoms of encrustation in the lumen of the catheter. As it is transparent, it can be visualised and evaluated.\u003cbr\u003eThe shank and tip of the catheter turn yellow to dark brown as the encrustation increases.\u003cbr\u003eThe catheter should be replaced when it becomes light brown in colour.\u003c\/p\u003e","brand":"RÜSCH","offers":[{"title":"Default title","offer_id":44463111307441,"sku":"RU8470004565171","price":9.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/8829\/4065\/files\/rush-sonda-brillant-silicona-24ch_0d801d59-8293-49a5-939a-fb5dad55ae03.webp?v=1784336127"}],"url":"https:\/\/farmaciasdirect-eu.myshopify.com\/collections\/urine-probes-12814.oembed","provider":"Farmaciasdirect.eu","version":"1.0","type":"link"}